PIMS - PMM Immunity Suite Software
The new "PMM Immunity Suite" (PIMS) software, accurately designed in terms of functions and user friendly approach, can manage the whole range of PMM components during both Test and Calibration processes, introducing the possibility of looking at the various monitoring tracks from generator, power meters and field sensors. The software is user friendly and provides a really ergonomic configuration which comfortably drives the operator through the various steps, from definition and selection of HW components to settings of required parameters and finally starting the test with "just one button". Program window has been designed for omni-comprehensive overview of each specific test being performed, so that operator can easily control all details with a quick glance. A graphical scheme of the test set-up clearly reminds about proper physical connections between components, which could slightly differ between Tests and Devices' Calibrations.
In case of Radiated Immunity Tests according to IEC/EN 61000-4-3 in Anechoic Chambers or TEM/GTEM Cells, PIMS does also include calibration of radiated field up to 16 points in the grid of Field Uniformity assurance, providing "Amplifier Saturation Check" routine for proper amplifier/antenna matching verification at 80% AM Modulation increased power.
Product description :
|
3030 - EMC Wide Band RF Generator, 9 kHz - 3 GHz |
3010 - EMC Wide Band RF Generator, 9 kHz - 1 GHz |
|
PMM 3030 is a powerful wide band RF signal generator, ideal for all EMC immunity test applications that has been designed adopting an innovative philosophy and state-of-art components. The model equipped with plug-in, rechargeable battery pack allows for ground loops-free operation and true portability. PMM 3030 features a particularly user-friendly interface based on a clear, bright display and function keys conveniently arranged. All settings can be done by the front panel keyboard and rotary knob.
MAIN FEATURES
- PMM 3030 9 kHz to 3 GHz frequency range
- PMM 3010 9 kHz to 1 GHz frequency range
- -107 to +10 dBm RF output
- Internal AM and pulse modulation
- Battery operation (mod. 3030-02)
- RS232/USB communication
- GPIB with external adapter
Product description :
|
SPECIFICATIONS
|
PMM 3030
|
Frequency range
|
9 kHz – 3 GHz
|
Frequency resolution
|
1 kHz
|
Frequency accuracy
|
± 10 ppm
|
Level range
|
-107 to +10 dBm
|
Level resolution
|
0.1 dB
|
Level accuracy
|
± 1 dB, level > -30 dBm
|
Output impedance
|
50& nbsp;ohm
|
RF output connector
|
N female
|
Spectral purity -harmonic
|
< -30 dBc @ 0 dBm, f > 1 MHz
|
AM modulation, internal
|
2 – 50 – 400 Hz, 1 kHz; 10% to 90%
|
AM modulation, external
|
2 Hz to 10 kHz; 10% to 90%
|
Input impedance
|
600 ohm
|
Input connector
|
BNC female
|
Internal pulse modulation
|
1 Hz: ON/OFF ratio @ 0 dBm > 40 dB 200 Hz: ON/OFF ratio @ 0 dBm > 40 dB
|
Remote control
|
RS-232, USB 2.0 (rear), User Port GPIB (external adapter)
|
User Port
|
RF OFF, RF ON, Start/stop test
|
Display
|
340 x 240 pixels, 16 gray levels
|
Display units
|
dBm, dBuV
|
Operating temperature
|
+10°C ÷ +40°C
|
Power supply
|
DC 10 – 15 V, 2.5 A
AC – DC adapter 115 – 230 V 50/60 Hz
|
Plug-in Battery pack (model 3030-02)
|
Li-Ion, rechargeable 3 h operation time (avg)
|
Dimensions
|
235 x 105 x 335 mm (WxHxD)
|
Weight
|
3.5 kg (mod. 3030-01) 4.3 kg (mod. 3030-02)
|
|
6630 - USB RF Power Sensor, 9 kHz - 3 GHz |
|
Accurate in laboratory, fast in manufacturing and solidly built for field applications
PMM 6630 is the ideal solution for RF power measurements in a wide variety of applications, including EMC immunity test systems to calibrate CDN and Clamps as well as to measure the input power of antennas or GTEM cells
Together with a directional coupler both direct and reflect power can be measured easily and precisely.
PMM 6630 is supplied with easy to use PC software to display the measurements in dBm, W, Vrms.
MAIN FEATURES
- 9 kHz to 3 GHz frequency range
- 100 nW to 1 W (-40 to +30 dBm) input range
- Excellent power linearity (0.2 dBm typical)
- True RMS response across 70 dB dynamic range enables accurate CW and modulated power measurements
- Low current consumption to save laptop battery
- No need for a Reference Calibrator
- Lightweight, convenient and easy to use with desktop and laptop PC
Product description :
|
SPECIFICATIONS
|
6630
|
Frequency range
|
9 kHz to 3 GHz
|
Power measurement range
|
100 nW to 1 W
-40 to +30 dBm
|
Max. input power
|
2 W peak envelope max. 300 ms
|
Power linearity
|
0.2 dB (-40 to +30 dBm @ 50 MHz; 25 °C ± 10°C)
|
Measurement accuracy 1, 2
|
< 0.35 dB
|
Measurement path
|
High: +30 to -9 dBm
Low: -9 to -40 dBm
1 dB typ. switching point hysteresis
|
Max. SWR
|
10 ÷ 300 kHz: 1.10 +30 ÷ -9 dBm
>300 ÷ 100 MHz 1.05
>100 MHz ÷ 1 GHz 1.10
>1 ÷ 3 GHz 1.25
10 kHz ÷ 3 GHz 1.20 -9 ÷ -40 dBm
|
Operating temperature
|
-10°C ÷ +50°C
|
Power supply
|
5 VDC – 100 mA from USB port
|
RF connector
|
N male, 50 Ω
|
PC communication interface
|
USB 1.0 – 1.1 – 2.0
|
PC Software settings
|
N° of Averages (1 to 1024)
Offset
Correction Factor
|
Measuring units
|
dBm, W, Vrms
|
Dimensions
|
30 x 30 x 95 mm (WxHxP)
|
Weight
|
0.12 kg
|
1. Max. SWR of source: 1.25